Abstract
Background
Implementation evaluation should focus on implementation success, guided by theories and frameworks. With high staff vacancies in the health services, it is important to consider pragmatic methods of data collection for implementation evaluation. This paper presents a cross-sectional rapid evaluation of a handheld medical device designed for remote examinations, piloted in Northern England. By using downloaded device data and administrative records mapped to domains from the implementation outcomes framework, this evaluation offers a pragmatic example of assessing implementation success.
Methods
The pilot design was pragmatic: sites volunteered, decided which services to use the device in, and launched when ready. The pilot and evaluation together lasted 1 year. Data was downloaded from the devices, and administrative records for the pilot accessed. Variables were mapped to five of the implementation outcomes, after reviewing with the device manufacturer and pilot team to assess robustness.
Results
N=352 care episodes were recorded using the device with 223 patients. Out of 19 sites ‘signed up’ to the pilot, 5 launched and delivered 10 of 35 proposed projects: a site and project adoption rate of 26 and 29%, respectively. Six sites signed up to an extension period; three had launched and three had not during the original timelines, indicating some sustainability. Feasibility was high, with only one in seven care episodes needing to be repeated due to poor device quality or error (sound/audio/internet). Fidelity of device usage was low for two of the eight available device examinations. Device and staffing costs were high but potential cost savings were attributable to fewer in-person appointments.
Conclusions
Through using device and administrative data, this evaluation minimised burden on busy healthcare staff yet was still guided by an evaluation framework. Five out of the eight implementation outcomes were measured, including sustainability and costs. The findings give insight into implementation challenges, particularly around adoption. For future research, it is recommended to engage with staff to prioritise outcome measurements and to focus on meaningful interpretation of indicators.
Background
Implementation success for healthcare interventions is crucial for the long-term sustainability of interventions, but it is often overlooked in favour of evaluating intervention effectiveness. Selecting the appropriate outcome measures is essential for evaluating implementation success as it allows for a comprehensive understanding of the implementation process and aids in the meaningful comparison of results across different studies and settings. Assessing implementation outcomes is vital for determining the overall success of an intervention as it provides a holistic understanding of the intervention’s performance and ability to be effectively implemented, adopted, and sustained in real-world settings [21]. Even if an intervention is highly effective, poor implementation can impede its overall effectiveness by limiting the number of people who are exposed to it or by delivering a suboptimal version of it due to low fidelity.
Over the past two decades, there has been a growing recognition of the importance of using theories and frameworks to guide health care intervention development, implementation, and evaluation. This facilitates a more targeted/systematic approach and helps to develop an evidence base. There are numerous papers on implementation determinants (barriers and facilitators) (e.g. [7]) and on the theories (e.g. diffusion of innovation, [22], models (e.g. COM-B, [14]), and frameworks (e.g. consolidated framework for implementation research, [4]) to guide exploration of these. And, they can also be used to guide evaluation design; for example, measuring barriers and facilitators pre and post intervention delivery to assess how well they have been targeted. Nilsen [17] provides a helpful overview and classification of the models, theories, and frameworks, for example, distinguishing between ‘determinant frameworks’ which provide a summary of implementation barriers and facilitators, ‘classic’ and ‘implementation’ (specific) theories which propose relationships between them and outcomes, and evaluation frameworks. Evaluation frameworks, such as Proctor et al.’s [21] implementation outcomes framework, focus instead on outcomes related to implementation success. Proctor et al. [21] propose the following eight implementation outcomes to be of importance. Adoption is defined as the uptake of a new intervention or programme. Penetration is the integration of the intervention within routine practice. Feasibility refers to the extent to which an innovation can be carried out in the given setting. Fidelity is defined as the degree to which an intervention is implemented as intended. Perceived acceptability refers to the level of utility the intervention has among the target population or stakeholders. Perceived appropriateness is the level of relevance, suitability, or fit of an intervention in the context of the organisation or target population. Sustainability is defined as the ability of an intervention to continue and maintain its effects over time. Finally, Cost refers to the financial resources required to implement and maintain an intervention, including innovation cost, the cost of the implementation strategy, and the location of service delivery.
Robust implementation evaluation can be challenging when working with healthcare organisations that have high staff vacancies (10.8% vacancy rate for registered nurses between April and December 2022, up from 10.2% the previous year, [15]). This can have knock-on effects for staff workload, wellbeing, and retention; issues intensified during the Covid-19 pandemic and addressed through the NHS People Plan [16] which focuses on recruitment and training, new ways of working, and developing an inclusive organisational culture. Implementation evaluators need to be cognisant of the challenges faced by healthcare organisations and take them into consideration. This involves striking a balance between engaging with health care staff to optimise implementation efforts, including evaluation, while trying to keep the additional workload manageable. The need to reduce burden for implementers and researchers has led to a growing focus on pragmatic measurement (e.g. [20, 25].
One pragmatic approach to implementation evaluation is making use of routine indicators, administrative data and, with the increasing attention on digital innovations in health care, downloadable data from health care devices. The latter arguably overcomes some of the shortcomings of traditional routine data such as electronic health records—including missing and unreliable data due to error in data entry [19]—through being device-specific and automated—e.g. a remote monitoring device providing data on device usage and duration of usage. We suggest that quantitative indicators such as these should be the first ‘port of call’ when designing an evaluation. This approach does not exclude the use of surveys and qualitative methods, as they provide valuable insights from the perspective of healthcare professionals and patients. Instead the emphasis is on first checking what indicators can be collected using routine or admin or device-downloaded data, and exploring for proxy measures where direct measures are not available, before then considering other ways of collecting data. Indeed, adopting a mixed approach that combines the use of indicators with short, targeted interviews allows for the exploration of constructs that may not be easily captured by indicators and routine data, while also keeping the length of interviews to a minimum. Making use of indicators not only reduces the demands on front line health care staff but also enables easier longer-term assessment of intervention sustainability through routine monitoring and potential benchmarking [11]. If existing indicators or device-downloadable data are available, the burden on operational health care staff (such as computing and quality improvement) should also be kept low.
Routine data usage in evaluation is not new, but has less frequently been theory/framework based, and where it has, has focussed on some implementation outcomes more than others. For example, a scoping review of quantitative indicators used in implementation research and evaluation [29] identified only 10 papers published between 2008 and 2018 that used such indicators to monitor intervention quality or implementation success. Of these, 5 papers used a theory or framework to guide indicator selection. When the 67 indicators across the 10 papers were mapped to Proctor et al.’s implementation outcomes framework to assess coverage of the different outcomes, fidelity and penetration rates were found to be most frequently reported, whereas appropriateness and sustainability were not measured. Costs, feasibility, adoption, and acceptability were also less frequently measured [29].
In this paper, we present an example of the administrative and downloadable device data used to evaluate implementation of a handheld remote monitoring device—‘TytoCare’—which is able to perform clinical grade audio and visual examinations of the heart, lungs, ear, throat, and skin. The examinations can be carried out by patients/carers themselves, following instructions generated by the device using the ‘Home’ version of the device, or carried out by health care professionals using the ‘Pro’ version of the device. The device was piloted across the Yorkshire and Humber region, England, for a programme of work on remote monitoring and virtual wards led by the Yorkshire and Humber Academic Health Science Network (Yorkshire and Humber AHSN). Remote monitoring is a crucial area of development in healthcare, enabling patients’ health to be monitored in their own homes. Remote monitoring is associated with better patient experiences [5, 18] and quality of care [2, 6, 27], more efficient use of healthcare professionals’ time [3], and wider system and societal benefits [1, 23, 24].
The data collected in this evaluation were used in conjunction with a small sample of qualitative interviews, analysed using the framework-guided rapid analysis approach [8]. The focus of this paper is on the device-downloaded and administrative data, with the aim of highlighting the issues encountered and areas for future research. Each implementation outcome measured was mapped to Proctor et al.’s [21] implementation outcomes framework.
Methods
The pilot launch began in June 2021 and ran until June 2022, spanning the second wave of the Covid-19 pandemic. To allow for additional data collection, a 3-month extension period was added to the pilot, ending in September 2022. However, data from this extension period is not included in this paper, as it falls outside of the scope and timelines of the original evaluation.
The device
The TytoCare device (Fig. 1) is a handheld remote monitoring device, able to perform clinical grade audio and visual examinations of the heart, lungs, ear, throat, and skin. The device has a camera for skin examinations and examination of the tonsils (a tongue depressor attachment aids this), temperature sensor, a stethoscope to examine lung and heart functioning, and an otoscope to capture images of the ear drum. As such, the device has potential to be used in a range of different care settings for monitoring of a range of different conditions. The ‘Home’ version of the device sits in the patient’s home and enables these examinations to be performed by the patient during a ‘live’ consultation (via a platform, similar to other online video systems), or alternatively, performed and submitted ‘offline/outside of a consultation’ by the patient for later review by the healthcare team. The device provides user-friendly instructions for patients for how to perform each examination as appropriate. The ‘Pro’ version of the device is designed for healthcare professionals, enabling cross site collaborations (for example, between general and specialised services) and their performing examinations for patients within the community, for example, a community nurse using the device in a care home and enabling a real-time or ‘offline’ review by a hospital specialist. The device requires internet connection for the live consultations and for the submission of examinations data.
Recruitment of sites
Sites (health care organisations, such as NHS foundation trusts and care homes) were based within three integrated care systems within the Yorkshire and Humber region of Northern England. No other restrictions were placed on participation. The Yorkshire and Humber AHSN (one of fifteen organisations established by NHS England in 2013 to spread health and social care innovation) released a call for interested healthcare sites to participate. Sites were free to choose the care setting and conditions to pilot in and with, and the most appropriate ‘device usage’ for them including which device to use. Device usage could include virtual ward set-up, e.g. monitoring patients at home or within a care home or cross site collaborations between general and specialist teams. A single site could host more than one pilot project; each care setting and chosen device usage was set up as a separate pilot project.
Context and data sources
Device costs were centrally paid for and centralised support was provided for implementation. The cost to sites was, therefore, restricted to staffing costs (using existing staff time) for planning the pilot at their site (device usage, care setting, benefit realisation), project management, and attending training. The evaluation team were not involved in implementation, which was completed by project teams and the commissioners/payers, the Yorkshire and Humber AHSN and the device manufacturer. The process comprised:
-
Scoping—project team, identifying aims, anticipated outcomes and benefits, scope, pathway/workflow design
-
Governance completion—Clinical Safety, Equality Impact Assessment, Data Protection Impact Assessment, Data Protection Contract
-
Network and IT testing and set-up
-
Training—clinicians, other health care professionals, administrative teams, patients, families, carers, first-line support
-
End to end testing
-
Communications to all required stakeholders
-
Final sign off and ‘Go-Live’
-
Post-live support
Available data for evaluation was:
-
Data downloaded from the device at pilot sites, detailing each episode of care where the device was used. Variables were as follows: whether the entry was a demonstration/test run, project, site, patient and clinician identifiers, date of care episode, duration, type of device (Home or Pro), the type of examination performed (ear, heart, lung, temperature, skin) and whether it was done using the device (for example, some examinations like temperature check could be done using standard equipment or the device). Device-downloaded data also included clinician responses to ‘pop-up’ questions that were programmed to appear after a real-time consultation or after their reviewing ‘offline’ submitted examination data. These asked clinicians to:
-
(1)
Indicate whether they considered the contact to have avoided a face to face appointment/accident and emergency visit as appropriate (yes/no)
-
(2)
Rate overall satisfaction and the audio and visual quality (on a 5-point scale)
-
(3)
Indicate whether the appointment had to be repeated due to poor quality (e.g. sound/visual, internet) or error (yes/no).
-
(1)
Clinicians were able to skip the questions.
-
Administrative data held by the pilot team:
-
◦ Records of interested sites, sites that went on to launch, sites that signed up for an extension period, associated dates.
-
◦ Documents detailing device licencing (numbers and cost), device type (Home or Pro) and how the device was being used (for direct consultations or offline reviews of examinations).
-
-
Training records: staff and patients (the latter, only applicable to patients coming into contact with the home version of the device).
The data was downloaded once at pilot end and supplied to the evaluation team by the device manufacturer. The data can be downloaded directly from a dashboard by clinicians/trusts/providers, for in-house monitoring.
Table 1 summarises the data sources and specific variables/indicators, and Table 2 summarises how these were combined (as appropriate) to provide implementation outcome measures mapped to Proctor et al.’s framework. Adoption was measured through comparing the number of sites and projects expressing an interest in the pilot (administrative records) with the number that went on to launch (downloaded data). Penetration was the number of clinicians trained (administrative data) who used the device (downloaded data). Feasibility was via a proxy: the proportion of care episodes which had to be repeated due to poor quality (e.g. sound/visual/internet) or error (using the third clinician’s pop-up question). Fidelity was also via a proxy: the proportion of examinations performed using the device (as intended for the pilot) versus not (e.g. checking heart rate with a standalone stethoscope rather than the device). Sustainability was estimated via the length of time projects and sites used the device and whether they signed up to the extension period.
The process for selecting these variables comprised the following 3 stages:
-
(1)
Reviewing the variables available in the device-downloadable data and the administrative data.
-
(2)
Selecting those that could be mapped to implementation outcomes.
-
(3)
Discussion with the device manufacturing company and the pilot team regarding the robustness of the indicators: did they measure what they appeared or purported to measure (validity), and reliably? Any issues that may reduce the reliability or validity of the measures were identified and followed by discussions to either address the issue if feasible, or discount the variable if too significant.
There was one variable dropped from the evaluation based on stage 3, detailed under the subheading ‘variable selection’ in the results.
Data cleaning and analysis
Data was exported into a statistical software programme, RStudio, for cleaning and analysis. Missing data was treated as missing data, and care episodes identified as demonstration/test runs linked to device launch or training were excluded from the analysis.
Analysis comprised:
-
(1)
Describing the sample (number of care episodes, number of sites and projects represented)
-
(2)
Running a frequency count for the one implementation outcome where no combining of variables was required: feasibility.
-
(3)
Combining variables where needed to generate the outcome measure (see Table 2: e.g. calculating adoption, sustainability, fidelity) and running frequency counts on the newly created variable/outcome.
-
(4)
The costs analysis. Costs were estimated from the perspective of the NHS and personal social services. Resources used in the pilot were identified by mapping the steps undertaken to plan and implement the pilot. This was done through project document review, speaking to project staff and a review of care pathways. An additional costing method file provides more detail regarding the methodology and calculation of device costs and project cost savings (see Additional file 1).
Results
Variable selection
Using the three-stage process to select variables for analysis, one planned outcome measure—penetration—was removed. This was due to concerns regarding the accuracy of the administrative data which recorded the number of patients and clinicians trained. Some sites had not kept their training data up to date, making the numbers unreliable (for example, more patients using the device than had been trained to use them which was not possible due to training being a prerequisite for receiving a home device).
The sample: sites, projects, and number of care episodes
A total of N=352 care episodes were conducted using the device, with 223 patients and 26 clinicians participating. Of the 19 sites that had signed up to participate in the pilot, 5 launched the device and hosted a total of 10 pilot projects (out of the original 35 proposed). Of these 10, 1 site used the device with working age adults in an emergency care department, 4 with older people (of which 1 was a GP practice and 3 were care homes), and 5—all acute care trusts—with paediatric patients and their families. The device was used to monitor respiratory patients for 3 projects (all paediatric settings), a range of conditions for 5 projects (the older people care settings and the emergency department setting), cleft lip and palate patients for 1 (paediatric) and palliative care for 1 (paediatric). Details regarding the sites, projects, device type and the way they used the device are summarised in Table 3. Codes are provided in all of the tables to avoid identifying sites and their projects, based on agreements for the evaluation.
Implementation outcomes
Adoption
-
Out of the 19 sites that had originally signed up to participate, 5 actually launched and used the device, resulting in a site adoption rate of 26%.
-
Similarly, out of the 35 projects that were originally proposed, 10 were launched, giving a project adoption rate of 29%.
Sustainability
How long the devices were used in each project are summarised in Table 4, alongside whether the projects signed up to the 3-month extension period.
Only three of the ten projects, each hosted at a separate site, continued to use the device up until the end of the pilot (June 2022). The average time that a project used the device was 5 months, but it should be noted that this is an underestimate as Site C Project 7 (Table 4) started using the device later on in the pilot and was still running at the end of the pilot. Six of the ten projects agreed to take part in the extension period until September 2022. This includes 3 sites that had already launched the project, and three that had expressed an interest but had not been able to launch during the original pilot timelines. This suggests positive perceptions of the device even among sites and projects that had stopped using the device before the original pilot end date.
Fidelity
Out of the 598 patient examinations that could have been performed using the device, 376 (62.88%) were recorded as having been done with the device, while 222 (37.12%) were not. Table 5 presents the number of examinations for each type of examination, and whether the device was used.
More examinations of patient’s temperature, throat, heart rate, and skin were made using the device than not. The use of the device when examining patient’s heart was the same as alternative methods. For examining patient’s lungs and ears, the device was less likely to be used than other methods available to the health care professional.
Feasibility
As can be seen from Table 6, out of N=86 clinicians who responded, 14% (N=12) reported that they had to reschedule appointments due to issues with the device. This indicates that approximately 1 in 7 appointments were impacted by poor device quality or error.
Costs
The estimated total cost of the pilot for the included projects was £920,545. The largest expenses were project management (52%) and device costs (36%). The estimated costs varied from £3270 to £27,389 for projects that were withdrawn from the pilot, and £41,068 to £96,977 for projects that went live. For projects with episode of care data available, the cost per patient ranged from £637 to £9761 and the cost per visit ranged from £479 to £6101. Table 7 provides breakdown of the estimated cost per visit.
A total of 132 patient appointments were avoided, resulting in potential cost savings to the NHS of £34,828 (Table 8).
Discussion
Implementation evaluators need to consider the current healthcare context, where staff vacancies are high and staff morale may be low and consider pragmatic methods of data collection first. In this paper, we present an example of how device-downloadable and administrative data was used to evaluate a remote monitoring device pilot study, framed around Proctor et al.’s [21] implementation outcomes framework. A small sample of qualitative interviews was also conducted at some of the participating sites and care settings to provide additional insights but this was not the focus of this paper.
Despite the budget and time constraints, our evaluation was able to measure five out of the eight implementation outcomes using quantitative indicators from device downloads: adoption, sustainability, fidelity, feasibility and cost. By comparison, the scoping review by Willmeroth et al. [29] found no papers using quantitative indicators of sustainability and appropriateness, and cost, feasibility, acceptability and adoption were also infrequently measured.
Even using quantitative indicators, evaluating all eight outcomes may not typically be feasible, as it may require additional administrative records to be kept or other data sources to be identified and linked, creating additional burden. Therefore, it is important to prioritise and focus on the most critical outcomes that align with the goals and objectives of the implementation project. In future research, we recommend sufficient time be allocated at the beginning of a project to engage key stakeholders in identifying the most critical outcomes to be measured, according to the chosen framework. This will allow for prioritisation of outcome measurement; recommended by Proctor et al. [21] and mirroring recommendations for patient and public involvement and engagement more broadly.
The indicators used in this evaluation give insight into implementation challenges. Notably, there were challenges for sites in launching the device. Despite this, there was still a desire to continue collecting data during the extension period for three of the five sites that launched. Additionally, three other sites, which had encountered challenges and were unable to launch during the original pilot timelines, expressed interest in re-joining and launching during the extension period.
Once launched, the feasibility of the device was demonstrated by the low number of care episodes needing to be repeated due to poor device quality (sound/visual/internet). The cost analysis indicated significant up-front cost for the device and staffing, but also potential savings to offset this cost from avoidable in-person appointments. However, the fidelity of the device was called into question by the proportion of examinations performed using the device versus other instruments, indicating that some of the device’s examination functions were not being used. Each of these implementation challenges was further explored through qualitative interviews, not covered in this paper, to give richer insight from which to develop recommendations for scale-up across other sites.
The pragmatics of evaluation design, of which administrative and downloadable data is one such example, is gaining traction in the literature. For instance, Hull et al. [12] reviewed the robustness of survey-based outcome measures which were mapped onto the implementation outcomes framework and scored these measures in terms of their practicality. This was conceptualised as the brevity of the measure, emphasising the importance of measures that are both psychometrically sound (having good reliability, validity and sensitivity to detect change) and brief, to minimise the burden on respondents and improve completion rates. Similarly, the rapid framework approach to the analysis of qualitative data, as outlined by Gale et al. [8], emphasises speed of analysis without sacrificing quality. This approach allows for a more efficient use of researcher time while still producing reliable and valid results. As demonstrated in their study, the rapid analysis yielded highly similar findings to those obtained through their comparative in-depth analysis. This is important as with low robustness, measurement becomes meaningless.
In the evaluation reported here, the reliability and validity of the indicators was considered through discussions with the device manufacturer and the pilot team to check that the variables measured what they appeared to measure, and that they did this reliably. The decision was taken to exclude the penetration outcome measures for both patients and clinicians due to project sites failing to update those records over time, making the data unreliable. This decision would not have been made without the participation of these key stakeholders. The need for valid and reliable measures is as relevant for indicators as it is for surveys and is an area still requiring effort in future research for both types of measures. Willmeroth et al. [29], for example, found only 2 of the 10 studies in their scoping review had indictors which met quality criteria laid down by the National Quality Forum (2017), while Lewis et al. [13] emphasise the need to assess the psychometric robustness of future survey measures. Weiner et al.’s [28] validated measures of feasibility, appropriateness and acceptability provide a good example of how the latter can be done. Nonetheless, for quick turn-around pilot evaluations such as this example, which lasted a year from start to finish, we suggest that the stakeholder engagement process is on par with checking the face and content validity of surveys. Additional robustness checks—for example, identifying other similar measures and then collecting and comparing scores to test convergent and divergent validity, could be particularly time consuming and need to involve additional operational health care staff. This is justifiable and right for large-scale research studies, but likely to be less amendable to smaller-scale pilots, where indicators may vary from project to project, especially those led by health care organisations.
Nonetheless, a limitation of this evaluation is the inability to confidently interpret the indicator data as, for example, high, middle or low adoption/feasibility/fidelity. Future research efforts, thus, should explore how best to interpret indicator data, in a more meaningful way, beyond simply reporting rates. For example, while we have been able to report adoption rates, the confident interpretation and classification of them as ‘high’, ‘moderate’ or ‘low’ has not been possible and is a limitation of this evaluation. When examining other implementation evaluation papers that have been guided by Proctor et al.’s framework (e.g. [9]) to help guide our interpretation, no firm rules were identified. Garner et al. [10] did suggest a cut-off point for interpreting fidelity rates based on evidence linking a particular number of intervention exposures and patient health outcomes, but this was relevant only in the context of their particular evaluation. Stiles et al. [26] examined different methods of calculating penetration rates, offering recommendations for best practice. However, interpretation was not the focus of their paper. Cut-off points or classifications may be less important when monitoring implementation over time or benchmarking, as the results can be interpreted relative to previous measures or other sites. However, clear and meaningful interpretation is essential for effective decision-making and action-planning irrespective of research design.
A further limitation is the lack of comparison across sites, taking into account their context and methods of device usage, which would have provided greater richness. The remit of the evaluation was broad and the timelines tight to include all sites and projects where the device was implemented and to focus on aggregated data, rather than focussing only on, for example, care home settings. The qualitative findings, not covered in this paper, provided more insight into care setting-specific issues and as such, we recommend that future research consider contextual variables a priori that data can be split by, and consider complementing the indicators with some qualitative data.
This paper does not attempt to claim that administrative and routine or downloadable data can solve all challenges of implementation evaluation. Indeed, there are limitations as outlined above. Further, the task of downloading and cleaning data, while reducing burden on frontline health care professionals, may still require involvement of operational staff, such as computing and quality improvement or audit teams. Further insights afforded by in-depth qualitative research and psychometrically robust survey measures such as those developed by Weiner et al. [28] are also incredibly valuable. Nonetheless, we argue that it is important for researchers to first consider using these data sources to measure implementation outcomes rather than relying solely on interviews and surveys.
Conclusions
This research has provided an example of a rapid evaluation of implementation of a remote monitoring pilot study, framed around Proctor et al.’s [21] implementation outcomes framework and using downloaded and administrative data to measure these outcomes. The results have shown that despite some limitations and challenges, the use of this data can provide valuable insights into the implementation process and success without adding substantially to healthcare staff burden. However, it is important to note that this approach should not entirely replace other methods of data collection, such as qualitative research and psychometrically robust measures where these are feasible. Future research should focus on finding a balance between the use of difference data sources and methods to ensure that implementation evaluations are both efficient and effective. Emphasis should be placed on robust measurement and interpretation of implementation indicators. Overall, this research emphasises the importance of considering and using different data sources in implementation evaluation to gain a comprehensive understanding of the implementation process.
Availability of data and materials
The dataset is not available due to data sharing agreements.
Abbreviations
- COM-B:
-
Capability, Opportunity, Motivation- Behaviour Model
- Yorkshire and Humber AHSN:
-
Yorkshire and Humber Academic Health Science Network
References
Bashshur RL, Shannon GW, Bashshur N, Yellowlees PM. The empirical evidence for telemedicine interventions in mental disorders. Telemedicine Journal of E-Health. 2016;22(2):87–113. https://doi.org/10.1089/tmj.2015.0206.
Brender J. Evaluation of health information applications–challenges ahead of us. Methods Inform Med. 2006;45(1):62–6.
Chumbler NR, Kobb R, Brennan DM, Rabinowitz T. Recommendations for research design of telehealth studies. Telemed E Health. 2008;14(9):986–9. https://doi.org/10.1089/tmj.2008.0108.
Damschroder LJ, Aron DC, Keith RE, Kirsh SR, Alexander JA, Lowery JC. Fostering implementation of health services research findings into practice: a consolidated framework for advancing implementation science. Implement Sci. 2009;4(1):50. https://doi.org/10.1186/1748-5908-4-50.
Elbert NJ, van Os-Medendorp H, van Renselaar W, Ekeland AG, Hakkaart-van Roijen L, Raat H, Nijsten TEC, Pasmans SGMA. Effectiveness and cost-effectiveness of ehealth interventions in somatic diseases: a systematic review of systematic reviews and meta-analyses. J Med Internet Res. 2014;16(4):e110. https://doi.org/10.2196/jmir.2790.
Feehan LM, Geldman J, Sayre EC, Park C, Ezzat AM, Yoo JY, Hamilton CB, Li LC. Accuracy of Fitbit devices: systematic review and narrative syntheses of quantitative data. JMIR Mhealth and Uhealth. 2018;6(8):e10527. https://doi.org/10.2196/10527.
Foy R, Walker A, Penney G. Barriers to clinical guidelines: the need for concerted action. Br J Clin Governance. 2001;6(3):166–74. https://doi.org/10.1108/EUM0000000005680.
Gale RC, Wu J, Erhardt T, Bounthavong M, Reardon CM, Damschroder LJ, Midboe AM. Comparison of rapid vs in-depth qualitative analytic methods from a process evaluation of academic detailing in the Veterans Health Administration. Implement Sci. 2019;14:11. https://doi.org/10.1186/s13012-019-0853-y.
Garcia-Cardenas V, Benrimoj SI, Ocampo CC, Goyenechea E, Martinez-Martinez F, Gastelurrutia MA. Evaluation of the implementation process and outcomes of a professional pharmacy service in a community pharmacy setting. A case report. Res Soc Admin Pharm. 2017;13(3):614–27. https://doi.org/10.1016/j.sapharm.2016.05.048.
Garner BR, Hunter SB, Funk RR, Griffin BA, Godley SH. Toward evidence-based measures of implementation: examining the relationship between implementation outcomes and client outcomes. J Subst Abuse Treat. 2016;67:15–21. https://doi.org/10.1016/j.jsat.2016.04.006.
Heidkamp R, Hazel E, Nsona H, Mleme T, Jamali A, Bryce J. Measuring implementation strength for integrated community case management in Malawi: results from a national cell phone census. Am J Trop Med Hygiene. 2015;93(4):861–8. https://doi.org/10.4269/ajtmh.14-0797.
Hull L, Boulton R, Jones F, Boaz A, Sevdalis N. Defining, conceptualizing and evaluating pragmatic qualities of quantitative instruments measuring implementation determinants and outcomes: a scoping and critical review of the literature and recommendations for future research. Transl Behav Med. 2022;12(11):1049–64. https://doi.org/10.1093/tbm/ibac064.
Lewis CC, Fischer S, Weiner B, Stanick C, Kim M, & Martinez R. Outcomes for implementation science: an enhanced systematic review of instruments using evidence-based rating criteria. 2015. Implement Sci: 10: 155. https://doi.org/10.1186/s13012-01509342-x
Michie S, van Stralen MM, West R. The behaviour change wheel: a new method for characterising and designing behaviour change interventions. Implement Sci. 2011;6:42. https://doi.org/10.1186/1748-5908-6-42.
NHS Digital. NHS Vacancy Statistics England, April 2015-March 2023, Experimental Statistics. May 2023. Available at: https://digital.nhs.uk/data-and-information/publications/statistical/nhs-vacancies-survey/april-2015---march-2023-experimental-statistics#:~:text=Key%20Facts,-Data%20from%20NHS&text=show%20a%20vacancy%20rate%20of,10.0%25%20(38%2C972%20vacancies). Accessed 01/06/2023.
NHS. We are the NHS: People Plan for 2020/2021- action for us all. July 2020. Available at: https://www.england.nhs.uk/wp-content/uploads/2020/07/We-Are-The-NHS-Action-For-All-Of-Us-FINAL-March-21.pdf. Accessed 1 July 2023.
Nilsen P. Making sense of implementation theories, models and frameworks. Implement Sci. 2015;10:53. https://doi.org/10.1186/s13012-015-0242-0.
Olff M. Mobile mental health: a challenging research agenda. Eur J Psychotraumatol. 2015;6:27882. https://doi.org/10.3402/ejpt.v6.27882.
Powell AE, Davies HTO, Thomson RG. Using routine comparative data to assess the quality of health care: understanding and avoiding common pitfalls. Qual Saf Health Care. 2002;12(2):122–8. https://doi.org/10.1136/qhc.12.2.122.
Powell BJ, Stanick CF, Halko HM, Dorsey CN, Weiner BJ, Barwick MA, Lewis CC. Toward criteria for pragmatic measurement in implementation research and practice: a stakeholder driven approach using concept mapping. Implement Sci, 12 (1), 118. https://doi.org/10.1186/s13012-017-0649-x.
Proctor E, Silmere H, Raghavan R, Hovmand P, Aarons G, Bunger A, Griffey R, Hensley M. Outcomes for implementation research: conceptual distinctions, measurement challenges, and research agenda. Admin Policy Mental Health Mental Health Serv. 2011;38:65–76. https://doi.org/10.1007/s10488-010-0319-7.
Rogers EM. Diffusion of Innovations (3rd Ed). The Free Press: New York.
Salmoiraghi A, Hussain S. A systematic review of the use of telepsychiatry in acute settings. J Psychiatric Pract. 2015;21(5):389–93. https://doi.org/10.1097/PRA.0000000000000103.
Seritan AL, Heiry M, Iosif A, Dodge M, Ostrem JL. Telepsychiatry for patients with movement disorders: a feasibility and patient satisfaction study. J Clin Move Disord. 2019;6:1. https://doi.org/10.1186/s40734-019-0077-y.
Smith JD, Hasan M. Quantitative approaches for the evaluation of implementation research studies. Psychiatry Res. 2021;283:112521. https://doi.org/10.1016/j.psychres.2019.112521.
Stiles PG, Boothroyd RA, Snyder K, Zong X. Service penetration by persons with severe mental illness: how should it be measured? The Journal of Behavioral Health Services & Research. 2002;29:198–207. https://doi.org/10.1007/BF02287706.
Vandenbroucke JP. Observational research, randomised trials, and two views of medical science. PLoS Med. 2008;5(3):e67. https://doi.org/10.1371/journal.pmed.0050067.
Weiner BJ, Lewis CC, Stanick C, Powell BJ, Dorsey CN, Clary AS, Boynton MH, Halko H. Psychometric assessment of three newly developed implementation outcome measures. Implement Sci. 2017;12:108. https://doi.org/10.1186/s13012-017-0635-3.
Willmeroth T, Wesselborg B, Kuske S. Implementation outcomes and indicators as a new challenge in health services research: a systematic scoping review. INQUIRY. 2019;56. https://doi.org/10.1177/0046958019861257.
Acknowledgements
We would like to thank the sites that supported this evaluation.
Funding
This report is independent research funded by the National Institute for Health and Care Research Yorkshire and Humber ARC (NIHR 200166). The views expressed in this publication are those of the author(s) and not necessarily those of the National Institute for Health Research or the Department of Health and Social Care.
Author information
Authors and Affiliations
Contributions
AH designed and lead the evaluation, and lead on the paper writing. NC led on the pilot roll out and contributed to the paper. NM led on the economic analysis and contributed to the paper. LB analysed the indicators data and contributed to the paper.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
The study was granted ethical approval from HRA, reference number: 21/LO/0684.
The researchers complied with the UK Policy Framework for Health and Social Care Research.
Consent for publication
Participants consented to participate and share their data. This was on a site by site basis. A data sharing agreement and data impact assessment were undertaken for the pilot as a whole. No one is personally identifiable within the datasets used for analysis and this publication.
Competing interests
The authors declare that they have no competing interests.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Additional file 1:
Additional costing methods. Table S1. Summary of assumptions used for training and meetings held during the device implementation used in the cost analysis. Table S2. Unit costs per type of resource. Table S3. Details of projects used in the cost analysis. Table S4. Visit types, number of patients and visits, and duration of visits for each project.
Additional file 2.
Standards for Reporting Implementation Studies: the StaRI checklist for completion.
Additional file 3.
Audit worksheet organized by manuscript or grant proposal section.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Hanbury, A., Mafirakureva, N., Chicken, N. et al. Evaluating change in a pressured healthcare system: a cross-sectional study of implementation outcomes using routine data indicators and proxies. Implement Sci Commun 4, 96 (2023). https://doi.org/10.1186/s43058-023-00471-x
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s43058-023-00471-x